ortho-Cresol and Phenol in Urine
Complete Kit, Order No. 53 000
o-Cresol is a minor metabolite of toluene and serves for the assessment of an exposure to toluene, which is a frequently used solvent in glues, paints and thinners. In contrast to hippuric acid (see order no. 52000), which is the main metabolite of toluene, o-cresol is no physiological component of urine and therefore reflects the internal exposure towards the polllutant.Phenol is the main metabolite of benzene and is used for the assessment to benzene as well as to phenol itself.The ClinTox® complete kit of RECIPE provides an excellent analytical sensitivity and enables a reliable biomonitoring of both analytes. The sample clean up is performed via solid phase extraction (SPE). |
|
Test Data |
HPLC Parameters |
|||||||||||||||||||||||||||||||||
|
|
Sample Preparation

Chromatograms |
||
| ClinChek® Urine Control, Level I | ClinCheck® Urine Control, Level II | |
![]() |
![]() |
|
| Phenol: 5.62 min, p-Cresol: 9.87 min, o-Cresol: 11.06, IS: 12.39 min | Phenol: 5.62 min, p-Cresol: 9.87 min, o-Cresol: 11.07, IS: 12.39 min | |
ortho-Cresol and Phenol in Urine
Complete Kit, Order No. 53 000
Ordering Information
| Order No. | Description | Quantity |
| 53000 | ClinTox® Complete Kit for o-Cresol and Phenol in Urine for 100 assays | 1 pce. |
| Kit Components (order no. 53000): | ||
| 53010 | Mobile Phase | 1000 ml |
| 53012 | IS Internal Standard | 5 ml |
| 9969 | Urine Calibrator, lyophil. | 5 x 10 ml |
| 52320 | Sample Preparation Columns | 50 pcs within the kit: 2 x order no. 53020 |
| 53021 | Reagent A | 400 ml |
| 53022 | Reagent B | 300 ml within the kit: 2 x order no. 53022 |
| 53023 | Reagent C | 25 ml |
| 53024 | Reagent D | 2 ml within the kit: 3 x order no. 53024 |
| Manual | 1 pce. | |
| Quick Reference | 1 pce. | |
| Start Accessories: | ||
| 52330 | Analytical Column with test chromatogram | 1 pce. |
| Accessories: | ||
| FK5810 | PEEK tubing (connection of prefilter and column) | 1 pce. |
| FK5820 | Stainless steel prefilter holder | 1 pce. |
| FK5821 | Replacement filter for stainless steel prefilter holder | 10 pcs. |
| ClinChek® Controls for toxic organic compounds: | ||
| 8867 | Urine Control, lyophil., Level I | 10 x 10 ml |
| 8868 | Urine Control, lyophil., Level II | 10 x 10 ml |
| 8869 | Urine Control, lyophil., Level I, II | 2 x 5 x 10 ml |