iris tech
iris technologies international gmbh
RECIPE products
- ClinRep© | Clinical Diagnostics |
HPLC
Complete Kits - ClinRep© | Therapeutic Drug Monitoring | HPLC
Complete Kits
- ClinTox© | Human Bio-
monitoring | HPLC
Complete Kits - ClinMass© | LC-MS/MS
- ClinCal© Matrix Calibrators
- ClinChek© Matrix Controls
- ClinTest© Solutions
- RECIPE News
BIOTICA products
MINERVA products
VMA, HVA and 5-HIAA in Urine | Automated Sample Preparation with Gilson® ASPEC™ XL Complete Kit, Order No. 3100 and 3200
As an alternative to the determination of VMA, HVA and 5-HIAA with manual sample preparation (see ClinRep® complete kit with order no. 3000), RECIPE offers appropriate ClinRep® complete kits for the use with automatic pipetting systems from RECIPE (see order nos. 3300-3400) and Gilson® (see below). There, the sample preparation and -injection is performed fully automatically.The ClinRep® complete kit for the determination of VMA, HVA and 5-HIAA with the automatic pipetting system Gilson® Aspec™ XL contains all reagents, that are required for analysis, including instrument adapted sample preparation columns. |
|
Test Data |
HPLC Parameters |
|||||||||||||||||||||||||||||||||||||||||||
|
|
Sample Preparation

Chromatograms |
||
| ClinChek® Urine Control, Level I | ClinCheck® Urine Control, Level II | |
![]() |
![]() |
|
| VMA: 3.67 min, IS: 5.50 min, HVA: 7.99 min, 5-HIAA: 11.80 min |
VMA: 3.62 min, IS: 5.46 min, HVA: 7.96 min, 5-HIAA: 11.77 min |
|
VMA, HVA and 5-HIAA in Urine | Automated Sample Preparation with Gilson® ASPEC™ XL Complete Kit, Order No. 3100 and 3200
Ordering Information
| Order No. | Description | Quantity |
| 3100 | ClinRep® Complete Kit for VMA, HVA and 5-HIAA in Urine(automated sample preparation with Gilson® Aspec™ XL) for 100 assays | 1 pce. |
| Kit Components (order no. 3100): | ||
| 3010 | Mobile Phase | 1000 ml |
| 3011 | Standard Solution, lyophil. | 5 x 1 ml |
| 3012 | IS Internal Standard | 100 ml |
| 3013 | Urine Calibrator, lyophil. | 5 x 5 ml |
| 3120 | Sample Preparation Columns | 50 pcs. within the kit: 2 x order no. 3120 |
| 3021 | A Ammonia Solution | 100 ml |
| 3022 | B Boric Acid Solution | 300 ml within the kit: 2 x order no. 3022 |
| 3023 | E Eluting Reagent | 100 ml within the kit: 2 x order no. 3023 |
| Manual | 1 pce. | |
| Quick Reference | 1 pce. | |
| 3200 | ClinRep® Complete Kit for VMA, HVA and 5-HIAA in Urine(automated sample preparation with Gilson® Aspec™ XL) for 500 assays | 1 pce. |
| Kit Components (order no. 3200): | ||
| 3010 | Mobile Phase | 1000 ml within the kit: 5 x order no. 3010 |
| 3011 | Standard Solution, lyophil. | 5 x 1 ml within the kit: 5 x order no. 3011 |
| 3012 | IS Internal Standard | 100 ml within the kit: 5 x order no. 3012 |
| 3013 | Urine Calibrator, lyophil. | 5 x 5 ml within the kit: 5 x order no. 3013 |
| 3120 | Sample Preparation Columns | 50 pcs. within the kit: 10 x order no. 3120 |
| 3021 | A Ammonia Solution | 100 ml within the kit: 5 x order no. 3120 |
| 3022 | B Boric Acid Solution | 300 ml within the kit: 10 x order no. 3022 |
| 3023 | E Eluting Reagent | 100 ml within the kit: 10 x order no. 3023 |
| Manual | 1 pce. | |
| Quick Reference | 1 pce. | |
| Start Accessories: | ||
| 3030 | Analytical Column with test chromatogram | 1 pce. |
| Refill Service: | ||
| 3031 | Analytical Column with test chromatogram | 1 pce. |
| (only if you send back your original column) | ||
| ClinChek® Controls: | ||
| 8820 | Urine Control, lyophil., Level I | 10 x 8 ml |
| 8821 | Urine Control, lyophil., Level II | 10 x 8 ml |
| 8822 | Urine Control, lyophil., Level I, II | 2 x 5 x 8 ml |