iris tech
iris technologies international gmbh
RECIPE products
- ClinRep© | Clinical Diagnostics |
HPLC
Complete Kits - ClinRep© | Therapeutic Drug Monitoring | HPLC
Complete Kits
- ClinTox© | Human Bio-
monitoring | HPLC
Complete Kits - ClinMass© | LC-MS/MS
- ClinCal© Matrix Calibrators
- ClinChek© Matrix Controls
- ClinTest© Solutions
- RECIPE News
BIOTICA products
MINERVA products
PCR Quantification Standards
for Highest Accuracy
Cat.-No. 52-0101 Legionella pneumophila
Cat.-No. 52-0112 Mycoplasma orale
Cat.-No. 52-0119 Mycoplasma pneumoniae
Cat.-No. 52-0116 Acholeplasma laidlawii
Cat.-No. 52-0117 Mycoplasma fermentans
Cat.-No. 52-0130 Mycoplasma hyorhinis
Cat.-No. 52-0440 Chlamydia trachomatis
Applications
The DNA standards can be used as a general control to confirm PCR system per formance using a qPCR instrument. Calibration curves are highly reproducible and allow the generation of highly specific, sensitive and reproducible data. The concentration of the Quantification Standard was determined photometrically and by qPCR. The DNA concentration was adjusted by dilution with DNA stabilizing buffer. Genomic DNA is used as a control template when DNA amplification tests by conventional PCR are performed (e.g. as contamination control in cell culturing). With the qPCR technology, this titrated DNA standard with a defined concentration of genome copies is used as calibrator to generate standard curves. Therefore the provided solution is diluted in a 10x dilution series with DNA-free water and used as a PCR sample. With the generated fluorescent data, the software provided with the qPCR instrument calculates a standard curve, which can be used to determine the DNA concentration of unknown samples.
Extraction
The quantification standard is genomic DNA extracted from low passage and de fined microorganisms. The extraction of the DNA is done by phenol/chloroform extraction with ethanol precipitation and column absorption methods. These DNA-Standards allow for the performance of a control reaction for PCR using qPCR instrumentation and to create a standard curve for quantification experiments, i.e. with Venor®Mp Mycoplasma pneumoniae Diagnostic Kit for qPCR. The DNA standards can be used as a general control to confirm PCR system performance using a qPCR instrument or for the validation of detection limits in respect to conventional PCR tests.
Contents
1 vial (green cap) of Standard DNA, 100 μl, contains approx. 106 genomes/μl.
3 vials (white cap) with 1 ml of Tris-HCl buffer, 10mM, pH 8.5.
